Changeset d7ba41f in subsurface


Ignore:
Timestamp:
Mar 24, 2017, 9:32:41 AM (2 months ago)
Author:
Dirk Hohndel <dirk@…>
Branches:
master
Children:
1355687
Parents:
58eeb3f
git-author:
Jan Mulder <jlmulder@…> (03/20/17 01:49:08)
git-committer:
Dirk Hohndel <dirk@…> (03/24/17 09:32:41)
Message:

user manual: set of small changes in planner text

Mostly typos and some wording change due to change of UI from
working pressure to starting pressure. And some subscripts changed,
some correction, some style. Now all are in ~2~ format.

Signed-off-by: Jan Mulder <jlmulder@…>

File:
1 edited

Legend:

Unmodified
Added
Removed
  • Documentation/user-manual.txt

    r58eeb3f rd7ba41f  
    12871287from an APD closed-circuit rebreather (CCR) dive computer:
    12881288
    1289         Dive Time (s)   Depth (m)       pO₂ - Setpoint (Bar)    pO₂ - C1 Cell 1 (Bar)   Ambient temp. (Celsius)
     1289        Dive Time (s)   Depth (m)       pO~2~ - Setpoint (Bar)  pO~2~ - C1 Cell 1 (Bar) Ambient temp. (Celsius)
    12901290        0       0.0     0.70    0.81    13.1
    12911291        0       1.2     0.70    0.71    13.1
     
    33883388_Log ->  Plan Dive_ from the main menu. It allows calculation of
    33893389inert gas load during a dive by using the Bühlmann ZH-L16 algorithm with the addition
    3390 of gradient factors as implemented by Erik Baker.
     3390of gradient factors as implemented by Erik Baker, or using the VPM-B model.
    33913391
    33923392****
     
    34133413
    34143414Like the _Subsurface_ dive log, the planner screen is divided into several sections (see image below). The *setup*
    3415 parameters for a dive are entered into the sections on the left hand side of the screen.
     3415parameters for a dive are entered into the sections on the left hand and bottom side of the screen.
    34163416They are: Available Gases, Rates, Planning, Gas Options and Notes.
    34173417
     
    34433443  as well as the gas composition within that cylinder. This is done in a similar way as for
    34443444  <<cylinder_definitions,providing cylinder data for dive logs>>. Choose the cylinder type by
    3445   double clicking the cylinder type and using the dropdown list, then specify the work
    3446   pressure of this cylinder. By leaving the oxygen concentration (O2%) field empty,
     3445  double clicking the cylinder type and using the dropdown list, then specify the start
     3446  pressure of this cylinder. By leaving the oxygen concentration (O~2~%) field empty,
    34473447  the cylinder is assumed to contain air. Otherwise enter the oxygen and/or helium
    34483448  concentration in the boxes provided in this dialogue. Add additional cylinders by using the
     
    34513451- The _Available Gases_ table includes three gas depth fields, labelled:
    34523452 ** Deco switch at: the switch depth for deco gases. Unless overridden by the user, this will be
    3453     automatically calculated based on the Deco pO preference (default 1.6 bar)
     3453    automatically calculated based on the Deco pO~2~ preference (default 1.6 bar)
    34543454 ** Bot. MOD: the gas Maximum Operating Depth (MOD) if it is used as a bottom mix. Automatically
    3455     calculated based on the Bottom pO preference (default 1.4 bar). Editing this field will modify the
    3456     O₂% according to the depth set. Set to ''*'' to calculate the best O₂% for the dive maximum depth.
     3455    calculated based on the Bottom pO~2~ preference (default 1.4 bar). Editing this field will modify the
     3456    O~2~% according to the depth set. Set to ''*'' to calculate the best O~2~% for the dive maximum depth.
    34573457 ** MND: the gas Maximum Narcotic Depth (MND). Automatically calculated based on the Best Mix END
    34583458    preference (default 30m / 98 ft). Editing this field will modify the He% according to the depth set.
     
    34993499
    35003500- Then define the cylinder size,
    3501   the gas mixture (air or % oxygen) and the starting cylinder pressure in the top left-hand
     3501  the gas mixture (air or % oxygen) and the working cylinder pressure in the top left-hand
    35023502  section of the planner under _Available gases_.
    35033503
     
    35833583bottom part of the dive (_bottom po2_) as well as for the decompression part of the dive (_deco po2_).
    35843584Commonly used values are 1.4 bar for the bottom part of the dive and 1.6 bar for any decompression
    3585 stages. Normally, a partial pressure of 1.6 bar is not exceeded. pO settings and the depth at which switching to a gas takes place can also be edited in the
     3585stages. Normally, a partial pressure of 1.6 bar is not exceeded. pO~2~ settings and the depth at which switching to a gas takes place can also be edited in the
    35863586_Available Gases_ dialog. Normally the planner decides on switching to a new gas when, during
    35873587ascent, the partial pressure of the new gas has decreased to 1.6 bar.
     
    40984098
    40994099If the graphical method doesn't work, pair the device from the command line. Open a terminal
    4100 and use +hciconfig+ to check the Bluetooth controller status
     4100and use +hciconfig+ to check the Bluetooth controller status.
    41014101
    41024102        $ hciconfig
     
    41224122Check that the status now includes +'UP', 'RUNNING' AND 'AUTH'+.
    41234123
    4124 If there are multiple controllers running, it's easiest to off the unused controller(s). For example, for +hci1+:
     4124If there are multiple controllers running, it's easiest to turn off the unused controller(s). For example, for +hci1+:
    41254125
    41264126        sudo hciconfig hci1 down
     
    41614161                bluez-simple-agent hci0 00:11:22:33:44:55
    41624162
    4163 Once ther dive computer is pired, set up the RFCOMM connection
     4163Once the dive computer is paired, set up the RFCOMM connection.
    41644164
    41654165===== Establishing the RFCOMM connection